Flame Arrestors

Flame Arrestors

In addition to standard designs, LISK custom-designs Flame Arrestors for critical applications including diesel engines, gas analyzers, storage tank vents, and aircraft fuel systems.

We work with your specific application to determine the final design, including media, volume of flammable media, flow-rate, allowable pressure drop, operating temperature, and distance from point of ignition or ignition location.

Features Include:

  • Custom designs to stop the propagation of a flame
  • Crimped metal ribbons (or elements) to provide maximum surface area and minimize pressure drop
  • Diameters currently up to 30″
  • We expertly select the appropriate material, coatings, and plating to suit your application
  • Components are designed to withstand extreme operating conditions including, but not limited to:
    • Corrosion
    • Temperature
    • Vibration
    • Pressure
  • On-site testing capability and strategic alliances to meet customer-specific test requirements
  • Cost-effective solutions that deliver quality, integrity, and high performance
  • LISK flame arrestors are designed to be used in Class I Division I & Class I Division II environments as defined by, NEC, NFPA, IEC. (as requested)